Decking

Timber and composite decks for backyards, entertaining areas and raised outdoor spaces. The size and height of a deck decide whether it needs approval and whether it needs a balustrade.

What's included

  • Footings and subframe
  • Timber or composite decking boards
  • Steps and landings
  • Balustrades where needed
  • Repairs and re-decking of existing decks

How the job runs

  1. Site visit

    We look at the job with you, talk through what you want, and take measurements. We also note ground levels, the height of the deck above ground, and where it sits in relation to boundaries.

  2. Written quote

    You receive a written quote that sets out the scope of work, what is and isn’t included, and any allowances for items you are still choosing.

  3. Approvals, if needed

    A small, low deck can be exempt development if it meets every standard. Larger or higher decks need approval, which should be in place before work starts.

  4. The work

    Set-out, footings and subframe, decking boards, then steps and any balustrade.

  5. Final walkthrough

    We go through the finished work with you and note anything that needs attention.

Standards & regulations

Deck work in NSW should meet the National Construction Code (NCC) and NSW planning rules. Relevant standards and rules include:

Exempt development limits
In NSW, a deck can be built without approval only if it meets every exempt development standard. These include a maximum area of 25 m², a floor no more than 1 metre above ground, an overall height no more than 3 metres, a position behind the front building line, and at least 900 mm from side and rear boundaries in most residential zones. Anything outside these limits needs approval.
NCC barrier rules (houses)
A barrier is needed where it is possible to fall 1 metre or more. On balconies, decks and landings the barrier must be at least 1 metre high, and on stairs at least 865 mm above the stair nosings. Openings must not let a 125 mm sphere pass through. Where a fall would be more than 4 metres, horizontal parts between 150 mm and 760 mm above the floor must not make the barrier easy to climb.
AS 1684.2:2021 Residential timber-framed construction — Part 2: Non-cyclonic areas
Covers the selection, placement and fixing of structural timber in houses and outbuildings, including alterations and additions. It includes floor framing, flooring and decking.
Before You Dig Australia
A free national service. An enquiry should be lodged before any digging so that owners of underground pipes and cables can send plans. The plans show approximate locations only.

Frequently asked questions

Not if it meets every exempt development standard, including a maximum area of 25 m² and a floor no more than 1 metre above ground. Otherwise it needs approval.

Under the NCC, a barrier is needed wherever it is possible to fall 1 metre or more. On a deck it must be at least 1 metre high.

Often, yes, if the subframe is sound. We check the footings and framing at the site visit before recommending new boards only.